    J Offline
    Jimin
    wrote on last edited by
    #1

    Hi I am new to Solibri and are trying to create my own rulesets at this moment and wonder if there is any way to remove all of pipes/ducts that are going vertical against the compound ceiling from the results?

    Lauri LuomaL 1 Reply Last reply
    0
    • Lauri LuomaL Offline
      Lauri LuomaL Offline
      Lauri Luoma Solibrians
      replied to Jimin on last edited by
      #2

      Hey @Jimin Try setting a “exception” in your intersection rule. The exception should remove clashes that are in 90 degree angle with the compound ceiling.
      da9b0e65-d906-4c73-9316-efd644ec6f66-image.png

      J ? 2 Replies Last reply
      0
      • J Offline
        J Offline
        Jimin
        replied to Lauri Luoma on last edited by
        #3

        @Lauri-Luoma oh wow! Thank you so much!

        But I wonder, what does the “protrusion 50mm” do?

        Lauri LuomaL 1 Reply Last reply
        0
        • Lauri LuomaL Offline
          Lauri LuomaL Offline
          Lauri Luoma Solibrians
          replied to Jimin on last edited by
          #4

          @Jimin If the minimum protrusion is set as 50mm, the duct/pipe has to protrude the compound ceiling at least 50mm to be excluded from the checking results. Ducts that won’t protrude at all (end up inside the ceiling) can’t be excluded.

          1 Reply Last reply
          0
          • ? Offline
            ? Offline
            A Former User
            replied to Lauri Luoma on last edited by
            #5

            Hello @lauri-luoma,

            @lauri-luoma said in Creating rulesets: Vertical MEP against compound ceiling:

            The exception should remove clashes that are in 90 degree angle with the compound ceiling.

            Is there a way to allow ducts that are not exactly at 90°?

            It would be useful in some cases (i.e. distribution elements going through a roof that has a slope).

            Best regards 🙂
            Mathieu

            Lauri LuomaL 1 Reply Last reply
            0
            • Lauri LuomaL Offline
              Lauri LuomaL Offline
              Lauri Luoma Solibrians
              replied to A Former User on last edited by
              #6

              Hey @mathieu-farine ,

              You could exclude those clashes with the normal filter (without going into the exceptions) in the rule with the “exclude” operator and defining e.g. the slab that is actually a roof. You would just need to know what parameter is unique for the tilted slab so that you can exclude only those slabs from the checking.

              Hope you got the idea! 🙂

              Best regards,
              Lauri Luoma

              ? 1 Reply Last reply
              0
              • ? Offline
                ? Offline
                A Former User
                replied to Lauri Luoma on last edited by
                #7

                @lauri-luoma thx for your quick answer! 🙃

                In that case that could be done yes but if there is a slight modelling error in the MEP part and that its elements don’t cross walls or slabs exactly at 90° I would get a problem although it is not (in my opinion).

                Wouldn’t it be possible just to get a toggle “exactly at 90°” per example?

                Lauri LuomaL 1 Reply Last reply
                0
                • Lauri LuomaL Offline
                  Lauri LuomaL Offline
                  Lauri Luoma Solibrians
                  replied to A Former User on last edited by
                  #8

                  @mathieu-farine

                  Ok, i understand. Unfortunately the degree is not currently possible to adjust.

                  Meaning that this is turning into a feature/improvement request in the existing rule 🙂 : https://society.solibri.com/category/18/feature-requests

                  Br,
                  Lauri

                  1 Reply Last reply