    Hi all,

    We are trying to create consistence rules about Site/Building/Storeys for a public administration, and we have some light questions about Solibri parameters VS IFC parameters, because Solibri do some conversion/re-interpretation, and we would like some clarification.

    I attached an IFC and 3 images , with the questions bout Pset Location.

    Q1 - Question about image 01_IfcSite:
    IFC has information about “Elevation” and “Global Bottom Elevation” , but Solibri seems that only shows one of them. It’s the interpretation of the image 01?

    Q2 - Question about image 02_IfcBuilding:
    Has the image the correct interpretation of the conversion from IFC to Solibri?

    Q3 - Question about image 03_IfcBuildingStorey:
    Has the image the correct interpretation of the conversion from IFC to Solibri?

    Thanks and best regards,
    Xavier Coll
    EiPM

    S50_P55_INT57_L58_ElevAct_CBshared.zip

    01_IfcSite.png

    02_IfcBuilding.png

    03_IfcBuildingStorey.png

    J 1 Reply Last reply
    1
    • J Offline
      J Offline
      Jim.persson
      replied to Xavier on last edited by
      #2

      @xavier I´ve had some troubles with this recentley and from what i understand global elevation i Solibri is not set from the Site value. I noticed this when coordination of files had diffrent Site values but still was in the correct Z height when combined. This wasn´t the case in another Softaware witch sets its Z heights from the Site value. I could Be wrong here but it´dosent seem to be so.

      So this topic is quite intersting.

      1 Reply Last reply
      1
      • T Offline
        T Offline
        twosk
        wrote on last edited by
        #3

        If files are exported from revit with real coordinates with PBP set at the project zero, i get these values.

        It would be great to know from where the information is taken or even a hint what setup is prefered.

        feedc73d-51bc-430b-ae06-99ac7d7c7aa8-image.png

        1 Reply Last reply
        0