  3. Ceiling Height ruleset

Ceiling Height ruleset

Scheduled Pinned Locked Moved Solved General Discussion
5 Posts 2 Posters 700 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • N Offline
    N Offline
    nho
    wrote on last edited by
    #1

    i am trying to get the ceiling heights from the floor to the suspended ceiling, but when i run a check, its checking the dimension from the suspended ceiling to the minimum height i had put in the parameter. What parameters do I have to set for Solibri to alert me when a ceiling is below the 2.29m minimum height from finish floor to suspended ceiling? See screenshots. I manually had to approve the ceiling heights that are correct, and reject the one that I knew was incorrect.

    Ceiling Height Ruleset Parameters.jpg Ceiling Height Screenshot error..jpg

    jakub.rusinJ 1 Reply Last reply
    0
    • jakub.rusinJ Offline
      jakub.rusinJ Offline
      jakub.rusin Solibrians
      wrote on last edited by
      #4

      Alright, try this:

      For Source Components (table on the left) - Only Slab
      For Target Components (table on the right) - Only Suspended Ceiling (and exclusions)

      image.png

      1 Reply Last reply
      0
      • jakub.rusinJ Offline
        jakub.rusinJ Offline
        jakub.rusin Solibrians
        replied to nho on last edited by jakub.rusin
        #2

        @nho said in Ceiling Height ruleset:

        More info on the rule is in on our help page:
        https://help.solibri.com/hc/en-us/articles/4406899817111-222-Component-Distance

        It may be the way you set up the filters for Source Component and Target Component.
        e2179483-ab85-4071-a1de-d010d2054937-image.png

        First, the “Floor” that you have in there is a container component, and I suppose those as such should not be used here
        a5689f75-5946-46fb-9f42-a1d8e5a91f57-image.png

        Instead try using Slab component.

        Secondly, the rule works in this way: set Slabs in the left filter and Suspended Ceiling in the right filter.

        Please see screenshots.

        This works on Solibri Building.ifc:

        3a62bbea-4f28-41e0-b860-f4d67e264702-image.png

        So

        What parameters do I have to set for Solibri to alert me when a ceiling is below the 2.29m minimum height from finish floor to suspended ceiling?

        1. Set the minimum height (as you already did)
        2. Try setting filters in the Source Component to be Slabs (instead Floors) and Target Components to be Suspended Ceilings
        1 Reply Last reply
        0
        • jakub.rusinJ jakub.rusin marked this topic as a question on
        • N Offline
          N Offline
          nho
          wrote on last edited by
          #3

          Hi Jakub, thanks for responding and for your explanation.

          I am still getting different results now where its checking the distance between different ceiling heights. I tried setting the container component as “slab” and “floor” but am still getting incorrect results. I also tried changing the order in which the components are listed, but still getting the same results. The picture below is showing the checking results im getting with the parameters (also screenshotted) below. Is there something else I should have changed?
          d346101e-67e8-483b-bd2c-dbea7e083f59-image.png

          c4bf5293-8a92-4cc0-9800-1614ffc72193-image.png

          1 Reply Last reply
          0
          • jakub.rusinJ Offline
            jakub.rusinJ Offline
            jakub.rusin Solibrians
            wrote on last edited by
            #4

            Alright, try this:

            For Source Components (table on the left) - Only Slab
            For Target Components (table on the right) - Only Suspended Ceiling (and exclusions)

            image.png

            1 Reply Last reply
            0
            • N Offline
              N Offline
              nho
              wrote on last edited by
              #5

              That worked! Thank you very much!! The parameters you had above measure from floor to ceiling.

              1 Reply Last reply
              0
              • jakub.rusinJ jakub.rusin has marked this topic as solved on
              • EricE Eric has marked this topic as unsolved on
              • EricE Eric has marked this topic as solved on