Skip to content
  • Categories
Collapse
Solibri Society Forum
  1. Home
  2. Comments & Feedback
  3. Tech Talks
  4. Twisted Space Naming

Twisted Space Naming

Scheduled Pinned Locked Moved Tech Talks
3 Posts 2 Posters 690 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • J Offline
    J Offline
    Juun Steen 0
    wrote on last edited by
    #1

    Gents,
    Twisted Space Naming.jpg
    Question:
    Why is Solibri twisting the Name and Longname of Spaces (see attachment).
    Can it be fixed with new release. Most of our clients is expecting the Name on Name and not on Number.

    Solibri read for Name the IFC " Longname" and for Number IFC “Name”. It should be the same as in BIMcollab Zoom or other applications.

    1 Reply Last reply
    5
    • PhilippP Offline
      PhilippP Offline
      Philipp
      wrote on last edited by
      #2

      Hi @Juun-Steen-0,
      I can understand your confusion but in my opinion Solibri follows the recommendation of buildingSMART when interpreting these attributes.
      1571e6c0-ebb0-43d6-92d8-6f6e90672646-grafik.png https://standards.buildingsmart.org/IFC/RELEASE/IFC4/ADD2_TC1/HTML/link/ifcspace.htm

      At least my intrepetation would be from it:
      Name = Unique room number
      LongName = Room name, which does not have to be unique.

      I would therefore not change anything in the mapping.

      Best regards,
      Philipp

      J 1 Reply Last reply
      -4
      • J Offline
        J Offline
        Juun Steen 0
        replied to Philipp on last edited by
        #3

        @philipp
        In some way I disagree1df576bc-1364-476e-b2a5-a884ee958df4-image.png

        Every Entity in IFC 2x3,TC1 has prescripted the Name on 3th position. That is what Solibri is reading as well, only not for spaces. There the IFC Name wil be defined in a property
        “Number”. So a new property for Name is introduced as “Number”. In some way it is not consistent.

        Strange enough the IFC script is doing what I’m asking (So the export is correct). Putting the Name on the right position. Only Solibri Interpretation is different and not aligned with most of the software like BIMcollab Zoom and other IFC readers.

        1 Reply Last reply
        4

        Copyright © 2025 Solibri Inc. | Powered by NodeBB