  3. Issues loose connection when updating model

Issues loose connection when updating model

Scheduled Pinned Locked Moved General Discussion
20 Posts 5 Posters 4.1k Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • JMannJ Offline
    JMannJ Offline
    JMann
    wrote on last edited by JMann
    #8

    And now the you mention it @tonigyllenberg, sometimes issues are deleted from the presentation after synchronization, saving, closing and re-opening the smc-file.

    That means the issues are synched to e.g. BIMcollab but can’t be found in the presentation in Solibri anymore. In the checking layout the issues are still there – but marked with the symbol that it hasn’t been added to a presentation yet:

    Bildschirmfoto 2020-04-16 um 10.58.52.png

    I can’t create this problem on purpose but will keep you updated when this happens again.

    COMPENDIUM BIM + Kybernetik
    https://www.linkedin.com/company/compendium-bim-kybernetik/

    1 Reply Last reply
    0
    • JMannJ Offline
      JMannJ Offline
      JMann
      replied to Matti on last edited by
      #9

      @Matti-Kannala said in Issues loose connection when updating model:

      If component type changes from Flow Segment to Duct or Column to Beam the results are lost in rechecking even the IFC Guid stays the same. This has been always the case in Solibri. Note: also this effects on many filters in rules, classifications and ITOs. The new component type might not be included in the existing filters. The results might change or be missing also due to this.

      In IFC2x3 there is no IFCDUCT entity like there is in IFC4. The component type (e.g. Duct) is selected based on the IFCTYPE entity (e.g. IFCDUCTSEGMENTTYPE).

      I believe that there is two possible cause for the problem that you encountered:

      1. The IFCDUCTSEGMENTTYPE is added the IFC file
      2. Solibri has been fixing issues in the IFC type import and in the earlier version the IFCDUCTSEGMENTTYPE was not imported correctly. Now the new version brings the type in and the component changes to Duct from IfcFlowSegment.

      We will check if the results could be some how preserved in case of change in component type.

      Isn’t it a big difference whether a component is changed from column to beam – I understand that case – and additional type information to one component in the updated model? IfcFlowSegment still is an IfcFlowSegment, The type alone shouldn’t affect the issue management when the entity and GUID stay the same. And the IfcName shouldn’t affect the issues also.

      Example:
      In a bigger office project the architects re-named walls for better connection to the cost management. This went terribly wrong. Some walls lost the information in IfcName and got the value “LEER” (=empty). That affected different kinds of walls e.g. inner and outer, walls with and without insulation. So the categorization changed, summed up the walls with the name “LEER” in one file of the tree and all issues concerning these walls were lost.

      COMPENDIUM BIM + Kybernetik
      https://www.linkedin.com/company/compendium-bim-kybernetik/

      1 Reply Last reply
      0
      • RicardoR Offline
        RicardoR Offline
        Ricardo
        wrote on last edited by
        #10

        A bit offtopic, but a tip for anybody who wants to run older Solibri versions to test things out; enable Hyper-V on Windows. This allows you to install a virtual machine on your computer, where then an older version of Solibri can be installed. So this eliminates the need to remove existing Solibri installations,

        https://docs.microsoft.com/nl-nl/virtualization/hyper-v-on-windows/quick-start/enable-hyper-v

        1 Reply Last reply
        0
        • agroniA Offline
          agroniA Offline
          agroni
          wrote on last edited by
          #11

          Also in my opinion this fault happens for some reason with the loss of either the IFC Entity, IFC Type or even both. It clearly visible at @JMann screenshots, in the first one you see the IfcFlowSegment and on the second (updated model) there is no IFC Entity for the same element. In both cases GUID is the same.

          I have tested also my models and came to the same conclusion. In my case the proxy element is an IfcBuildingElementProxy when I did the first check, respectively issue slide. In the next model update, the IFC Entity is missing, and also the Issue connectivity to those elements is gone.

          AllesWirdGut Architecture
          www.awg.at

          1 Reply Last reply
          0
          • tonigyllenbergT Offline
            tonigyllenbergT Offline
            tonigyllenberg Solibrians
            wrote on last edited by
            #12

            Thank you for the additional information. We will discuss this internally to see if there is a way that results could somehow preserved in case the component type changes. And of course, if you have models which can be shared for testing and development, they are always welcome and much appreciated!

            Kind regards,

            Toni on behalf of the Solibri team

            1 Reply Last reply
            1
            • JMannJ Offline
              JMannJ Offline
              JMann
              wrote on last edited by
              #13

              Thank you @tonigyllenberg!

              COMPENDIUM BIM + Kybernetik
              https://www.linkedin.com/company/compendium-bim-kybernetik/

              1 Reply Last reply
              0
              • JMannJ Offline
                JMannJ Offline
                JMann
                wrote on last edited by
                #14

                Hey @tonigyllenberg,

                is there an update or workaround for this topic?

                Thank you!

                COMPENDIUM BIM + Kybernetik
                https://www.linkedin.com/company/compendium-bim-kybernetik/

                1 Reply Last reply
                1
                • tonigyllenbergT Offline
                  tonigyllenbergT Offline
                  tonigyllenberg Solibrians
                  wrote on last edited by
                  #15

                  Hello @JMann,

                  My apologies for the delay! The matter was discussed internally, and we have an issue created for implementation. The issue has currently not been selected for development, however we are planning on making improvements to checking features in the near future, and at the same time we will open the issue up again.

                  Kind regards,

                  Toni on behalf of the Solibri team

                  1 Reply Last reply
                  1
                  • JMannJ Offline
                    JMannJ Offline
                    JMann
                    wrote on last edited by
                    #16

                    Thank you @tonigyllenberg for your reply! Can’t wait for the progress!

                    COMPENDIUM BIM + Kybernetik
                    https://www.linkedin.com/company/compendium-bim-kybernetik/

                    1 Reply Last reply
                    1
                    • JMannJ Offline
                      JMannJ Offline
                      JMann
                      wrote on last edited by
                      #17

                      Hey @tonigyllenberg,
                      do you have an update on this topic?

                      COMPENDIUM BIM + Kybernetik
                      https://www.linkedin.com/company/compendium-bim-kybernetik/

                      1 Reply Last reply
                      0
                      • tonigyllenbergT Offline
                        tonigyllenbergT Offline
                        tonigyllenberg Solibrians
                        wrote on last edited by
                        #18

                        Hello @JMann,

                        Although the issue has been looked into before, it has not yet been selected for development. This issue falls under Checking improvements, which we have an extensive list of. Once we begin working more on checking related items, we will revisit this topic.

                        Kind regards,

                        Toni on behalf of the Solibri team

                        1 Reply Last reply
                        0
                        • JMannJ Offline
                          JMannJ Offline
                          JMann
                          wrote on last edited by
                          #19

                          Hey @tonigyllenberg,
                          are there any updates on this issue? Thanks in advance!

                          COMPENDIUM BIM + Kybernetik
                          https://www.linkedin.com/company/compendium-bim-kybernetik/

                          1 Reply Last reply
                          0
                          • tonigyllenbergT Offline
                            tonigyllenbergT Offline
                            tonigyllenberg Solibrians
                            wrote on last edited by
                            #20

                            Hello @JMann,

                            Unfortunately we don’t have any updates on the topic yet. At the moment we are currently not working on checking improvements, and this item has not been selected for development.

                            Kind regards,
                            Toni on behalf of the Solibri team