1.2k Topics 5.2k Posts
  • Obtain Nearest Space Number for elements

    5
    0 Votes
    5 Posts
    1k Views
    K

    Thanks Simon.

  • 5 Votes
    7 Posts
    2k Views
    violarenzoniV

    @Pasi-Paasiala Thank you very much! I use the 24.5.0.31 Solibri Version.
    Yes I have unticked that but the condition remains the same:
    1.jpg

    Thank you @Pasi-Paasiala and @Paul-Linder for adding the issue!
    Bye,
    Viola

  • Save all classifications at once

    3
    3 Votes
    3 Posts
    858 Views
    HechtwieFischH

    @Solibrians Is there any way to do this besides exporting them one at a time?

  • Classifications and rulesets

    1
    0 Votes
    1 Posts
    348 Views
    No one has replied
  • BIM360 / ACC integration not working

    25
    3 Votes
    25 Posts
    10k Views
    Sini AaltoS

    @JeroenKoomen yes it should be ok: we got in contact with Autodesk and the change of endpoints is indeed happening. They added us to the list of customers that get extra time until the 31st of July. The reason why we don’t need to make a hotfix release is that contrary to the earlier information we had, the required changes can only be done in the backend, which doesn’t require a new release. We have already implemented the changes in the backend but it may take some time until they become effective i.e. when V2 endpoints are in use. There should anyway be much enough time for that to happen before the end of month. So everything should be fine but we’ll follow up the situation in case problems would arise.

  • Bug with marked comments in communication?

    1
    2 Votes
    1 Posts
    407 Views
    No one has replied
  • Displaced wall after model update

    6
    0 Votes
    6 Posts
    2k Views
    BvanDalsumB

    Today i had the same kind of problem with missing elements, if i open the IFC as a stand alone the element are present. if i update the ifc in the SMC they are still missing.
    removing the ifc totaly from the SMC and ADD the model then the missing elements appear.

    this totaly makes updating models not reliable and is an absolute a no go for using Solibri

    tried solibri 9.13 and 24.5 with the same result.

  • fixture shining upwards

    6
    0 Votes
    6 Posts
    957 Views
    H

    where can I make a request for this?

  • Ruleset: Stud opening clash

    3
    0 Votes
    3 Posts
    606 Views
    S

    This should be resolved in the latest build of the Fire Stopping rules, the issue is related to components distance from the origin. We now transform the Door to the origin create the studs and re-position to carry out the clash.

  • NG description has a strange information

    7
    0 Votes
    7 Posts
    2k Views
    H

    @Matti-Kannala So as I understand, the Location will auto regenerated for comp that has spaces in relation and it will not appear if the comp doesn’t have any spaces in relation.

  • Calculate COBie Greyed out

    2
    0 Votes
    2 Posts
    572 Views
    S

    Hi, This is a known bug and is logged to be fixed. The COBie project has to be the first project opened once Solibri is started otherwise this happens. Simply close the project (save if required), shutdown Solibri and then restart Solibri opening the same project, load your COBie settings and the calculate button should now be available.

  • Checking unwanted and unnecessary Properties

    8
    1 Votes
    8 Posts
    3k Views
    P

    @agroni If the property sets you accept follow some naming pattern, you could have a regular expression that matches all other property set names and prohibit all properties in those with a regular expression matching any string.

  • Checking properties against a regex

    1
    1 Votes
    1 Posts
    339 Views
    No one has replied
  • BIM360 integration not working (fixed)

    2
    0 Votes
    2 Posts
    696 Views
    B

    Edit: Integration seems to work again. Not sure why.

  • Model comparison between two models from different programs

    1
    0 Votes
    1 Posts
    433 Views
    No one has replied
  • MEP Duct to ifcopening through wall rule?

    Unsolved
    4
    1 Votes
    4 Posts
    1k Views
    S

    Hi Mathieu, The Identification rule has a check box for identifying where this occurs
    Check the option and the supply the component that it needs to cross i.e. a BWIC or Fire Seal using the filter / filter with classifications.

    image.png

    We have a update coming soon to this rule which will allow you to check for different scenarios.
    image.png

  • Troubles setting up SOL 203 from Revit

    Solved
    3
    0 Votes
    3 Posts
    887 Views
    J

    230 works like a charm. Thanks for helping out!

  • Confusion about Topic ID’s

    2
    0 Votes
    2 Posts
    575 Views
    A

    Were you ever able to resolve the issue? A client of ours has the same problem and we’re not sure whats causing it. Now we have a ton of duplicates in our Database. Did the problem go away by itself and do you know at what Version it stopped?

  • Bug: can't edit layout if role is not loaded

    1
    0 Votes
    1 Posts
    373 Views
    No one has replied
  • Rule checking performance

    1
    3 Votes
    1 Posts
    442 Views