Skip to content

General Discussion

Let's talk Solibri!

1.2k Topics 5.2k Posts
  • 0 Votes
    4 Posts
    1k Views
    JeroenKoomenJ

    Hi Ion,

    Be aware that a level in Revit is not allways exported as a building storey in IFC. This has to do with settings in revit and export settings. If an element in Revit is hosted on a level that is not exported to a building storey in IFC… it will be matched to another building storey.
    Hope you understand. Only levels that are marked “building storey” in Revit will be exported to IFC.

    Jeroen

  • Reordering 'Issues' Categories Doesn't Work

    Solved
    3
    0 Votes
    3 Posts
    799 Views
    C

    @JohanE Thank you for telling me that…I don’t think I would have ever figured that out!

  • Creating rulesets: Building Height

    1
    0 Votes
    1 Posts
    269 Views
    No one has replied
  • Merge IFC

    2
    0 Votes
    2 Posts
    858 Views
    JeroenKoomenJ

    Hi @petrinnn,

    That is not possible in Solibri.
    Offcourse it can be done with other software tools, like SimpleBIM.

    Other workaround is to make a copy of your revit model, bind links in this copy and then export to IFC.
    Only use this copy with binded links to export to IFC.

    This is not really a question for this forum by the way 🙂

    Kind regards,

    Jeroen

  • Objects Not Showing in Presentations

    1
    -1 Votes
    1 Posts
    351 Views
    No one has replied
  • 1 Votes
    2 Posts
    589 Views
    MattiM

    You can try to add this line to Solibri options file:
    C:\Program Files\Solibri\SOLIBRI\Solibri.vmoptions

    -Dmodel-volume-max-layers=5

    This limits the buildings total volume calculation to 5 horizontal layers.
    Note: This lowers the accuracy.

  • Filter Corner Pipe with Component Distance Rule 222.4.1.

    2
    0 Votes
    2 Posts
    544 Views
    MattiM

    Could you describe your idea more detail?

    Is there a component that represents “the corner”? The same service means the same System? What is the goal for the check?
  • Checking Result Icon Doesn't Show Accepted

    2
    0 Votes
    2 Posts
    538 Views
    Lauri LuomaL

    If you have filtered the results you might end up in a situation like in the picture. Please make sure you don’t have any of the results filtered out in the results window:

    04b2b97a-047e-4dc0-b84a-7c915750f9d3-image.png

    If you have this option set to “no filtering” and you still get this issue, update to the latest version and see if the problem still occurs. If so, please send a bug report to our [email protected]

    thank you!

  • Calculation definitions (wall gross area)?

    7
    0 Votes
    7 Posts
    2k Views
    mpanceraM

    please do so!
    but first completely support IfcMaterialLayer and a easy understandable user interface for them / or give the users some nice help tutorial videos

    thanks

  • How to get length property of pipe?

    3
    1 Votes
    3 Posts
    861 Views
    S

    Hi, If the model is created in Revit initially then you can make sure that the parameters that control the object are exported. These parameters are contained in the dimensions properties. These can be exported by checking the Export Revit property sets or by mapping these parameters only using a mapping table associated to the export. These parameters can then be used in your rules.

  • Customize results description

    2
    0 Votes
    2 Posts
    771 Views
    MattiM

    @Bimiser

    The customization can be done at least by using Manual Checking Rule #232.

    Go to Ruleset Manager

    Drag a new Manual Checking Rule #232 under your rule you want to customize
    e248a256-e1f2-4e71-87bf-39c8f1652cf0-image.png

    Set your rules “Sub Rule Options” to check only failed components
    6297c6f3-4d5e-418a-856a-6f0b0a5bd4de-image.png

    Customize the categories, issue names and descriptions for specific components (filters)
    f1ecfa4c-532a-4094-9dd4-59db92afed03-image.png

  • IFC from BIG Revit models

    10
    0 Votes
    10 Posts
    2k Views
    dserdiukovD

    But, thanks a lot for idea

  • IFC definition of Door Swing

    9
    0 Votes
    9 Posts
    4k Views
    R

    @b-huijskes Thanks for your reply.
    @Solibrians is this a function we can expect in upcoming Solibri releases in the near future? And, maybe a little off topic, but being new to the Solibri Society, I was wondering if there is a roadmap of the developments and features Solibri is working on that can be shared here?

  • Optimized Rule Tree Level

    1
    0 Votes
    1 Posts
    227 Views
    No one has replied
  • Statistics from SSC on use of product type

    7
    0 Votes
    7 Posts
    2k Views
    L

    Ok, thank you. I think this would be a Nice feature to have in the future.

    Regards

    Leif

  • Participants needed for thesis research

    2
    3 Votes
    2 Posts
    411 Views
    Mats_KnutssonM

    Hi Solibri,

    For your development I suggest:

    *looking at how the UI of Solibri could improve to leverage the strenghts (existing and new) of the program.
    *adding data cleaning possibilities like SimpleBIM.

    Cheers,
    Mats

  • New licensing + firewalls

    9
    0 Votes
    9 Posts
    2k Views
    K

    @cpreidel Thanks for the update. It appears to be working better now.

    Regards,
    Karl

  • Call for your help | Solibri Labs

    1
    0 Votes
    1 Posts
    514 Views
    No one has replied
  • Solibri Viewer Registration versus Anywhere

    2
    0 Votes
    2 Posts
    848 Views
    hkringsKUBUSH

    @JeroenKoomen - As far as I know the SMV registration is deprecated and replaced by the new Solibri ANywhere registration (https://www.solibri.com/download-Solibri-anywhere)

    @Solibrians , I’d like to add to this message.

    I’ve been contacten by users who have a SSC-account and want to start the Solibri Model Viewer by opening the Solibri Model Checker as the license is unavailable. (This is a workflow we’ve recommending for a while as the Solibri Model Viewer registration was not working)

    Instead of starting the SMV, the user is redirected to a registering page for the SMV. However, registering for the SMV is not possible anymore and should also not be needed as they have a SSC-account.

    Could you give more information on how/whether the SMV can still be used and in which scenario the customer needs to install the new Solibri Anywhere?

  • Admin tools gone from solution.solibri.com?

    12
    4 Votes
    12 Posts
    3k Views
    ?

    @dbaldacchino Thanks for letting us know that it works!

    I noticed that in the Assignment tab, the columns are not arranged correctly. If you scroll to the right you will see 9.10 column between 9.5 and 9.1

    I will fill a bug about it.

    Thanks!

    –
    Jose

Copyright © 2025 Solibri Inc. | Powered by NodeBB