@JSN
Then it partially explains, the level hierarchy is not taken by global coordinates, but by Top and Bottom elevation (properties) (*sea level or project), and the problem might lie inside of different software.
AR model is done in Revit, where is possible to export project coordinates and shared coordinates which include sea level, by defining sea level height - the top and bottom elevation in Solibri will show sea levels.
And EL model is done in CADmatic, and they have set floor heights by project heights.
and there is no such thing as a project or shared coordinates, where the model is set - that’s what you export. (with or without coordinates)
And seems that this explains the problem 🙂
As Solibri is unifying software maybe would be possible to integrate if there would be a possibility to pick by what the flooring hierarchy is done - top and bottom elevations or global Z elevation
This would solve some problems if the project is already done, for example,
we gonna test, EL gonna set the floor height by sea level and see if this works, or any other solution I will post an answer here. 🙂
Thanks.