Skip to content

General Discussion

Let's talk Solibri!

1.1k Topics 5.1k Posts
  • Why are issues created when rules are fulfilled?

    Locked Solved
    5
    0 Votes
    5 Posts
    1k Views
    M

    The new version will use UTF-8 by default. 🙂

  • BCF Live Connector Presentation

    4
    0 Votes
    4 Posts
    1k Views
    Harmen JorritsmaH

    You cant’t link a issue in Solibri with a issue in BIM Collab.
    You can make a BCF report in BIM Collab and load this in Solibri. Than you have an linked issue between Solibri and Bim Collab.
    The snapshot shows a issues created in de ruleset.
    When you create new issues in the ruleset you have to use the presentation section in Solibri.

    When you import the issues from the ruleset you get them from the presentaion

    image.png

    Wou can create the presentation form the ruleset by clicking the right mouse button en the create presentation.
    02c26b9b-cae6-4984-84f4-5bc7b7ba8a64-image.png

    When you create new issues in the ruleset, you can update the presenmtation with the results from the ruleset.
    a7429845-3351-4d2b-aee0-56a3862e9639-image.png
    1273db00-f4cb-4f47-86a1-c4de078b31bc-image.png
    Select the new issues in the presentation witch you want to sent to BIm Collab.
    62938b5e-a589-4f41-872c-c11f8112f6de-image.png
    Import the seleted issues in BIM Collab
    3d82ffa1-c9db-4d93-b31a-0419b98332a9-image.png
    You see in the BCF Live Vieuw the issues. The triangle shows that this issues coms from the ruleset, imported via presentation.
    e84ae789-c4e0-45f7-9ebe-1f0280055c6b-image.png

  • Basket Presets

    2
    0 Votes
    2 Posts
    554 Views
    A

    Sorry, I should have searched the forum before.
    Here is the solution: https://society.solibri.com/topic/1477/remove-saved-selection-basket?_=1692949687857

  • Check gross area of a clash between components

    2
    0 Votes
    2 Posts
    622 Views
    MattiM

    “Is it possible to generate a report on the total gross area of clashes and export the results in an Item Takeoff (ITO) format?” is not possible.

    Relating to this topic you can do much:

    With ITO you can list nearest walls of the spaces using relation column. This is a bit advanced. Please ask if you need help. Discpline, Shortname or Model name can be used in filters to find components spaces or walls from some specific models. Rule 202 is good for validating spaces that should go along the walls Rule 222 can be used for checking the distance to the wall. Rule 1 can be used for checking the clashes. This rule generates a report of total clash volumes.

    image.png

  • Small components and SOL/234/1.2 issue

    2
    0 Votes
    2 Posts
    775 Views
    M

    Hello,
    I have the same problem at the moment. This rule used to work for me, but the only result I’m getting now is: “No Inner Components” and “Orphan Inner Components”.
    There are some visually present issues, but I’m unable to get these in my Results by tweaking the Parameters…
    Could there be a bug?

  • filter several classifications at once

    6
    0 Votes
    6 Posts
    1k Views
    S

    If you are using the Any value for both lines then components can’t be classified in both as stated the two lines with the same Solibri Component will behave as an And not a Or operator. What you can do if the Classifications are not too large is to create an additional single classification which classifies these values into one classification, you can then use the single line in the filter that accesses this new classification.

  • Compartmentation

    5
    0 Votes
    5 Posts
    1k Views
    P

    @Mohammadi Please clean your selection basket first. You can clean it either in Selection Basket view or in 3D’s popup menu (Selection Basket/Empty Selection Basket).

  • IBC

    3
    0 Votes
    3 Posts
    772 Views
    P

    @Mohammadi You may have been using the ADA and ABA accessibility extension that is available in Solibri Solution Center.

    In Solibri Go to File/Solution Center. If the extension is assigned to you, you should see it there. If not, you need to get it assigned to you in Solibri Solution Center by somebody that has admin rights in Solibri Solution Center.

  • Solibri Model Colors

    5
    0 Votes
    5 Posts
    1k Views
    B

    If you select Enable Visualization, do you get different results?

    c383174f-bbc5-432c-8f6e-e5cccabf8d5f-afbeelding.png

  • Solibri digest / email notifications don't work anymore

    Locked Solved
    7
    0 Votes
    7 Posts
    1k Views
    EricE

    The latest update has fixed the issue though if anyone still has issues with the digest please report, thanks!

  • 0 Votes
    3 Posts
    747 Views
    P

    @scorney What do you mean by volume here? Would you only want to check components that are larger than a given volume?

  • Fire exit space

    Locked Solved
    6
    0 Votes
    6 Posts
    1k Views
    P

    @Mohammadi Based on your screenshot, there are no spaces matching your filter. You should see this also in your Results view. You need to fix your filter first.

  • SPACE GROUPING

    Solved
    4
    0 Votes
    4 Posts
    1k Views
    jakub.rusinJ

    @Mohammadi said in SPACE GROUPING:

    where i can find space grouping?
    in below screenshot

    If you are asking about the Space Grouping Classification that comes installed with a Solibri, as a resource it is located by default here:

    C:\Users\Public\Solibri\SOLIBRI\Classifications\Space Grouping.classification

    You can open it within Solibri via Open button in Classification View:

    899bfcbe-a6c7-4f00-8007-d378528d2cd3-image.png

    db13a4e6-5915-44a7-b556-032b8462dd07-image.png

    a5893bdb-4b5d-42dc-8715-bca5d659bca4-image.png

  • Distance from ProvisionForVoid to the end of a wall

    9
    0 Votes
    9 Posts
    2k Views
    K

    @chs This looks interesting! I will test it after my vacation.
    Thanks for the tip.

    Greetings, Kai

  • Fire rated walls, door, and windows

    Solved
    2
    0 Votes
    2 Posts
    759 Views
    jakub.rusinJ

    @Mohammadi said in Fire rated walls, door, and windows:

    Can we change a walls, doors and windows properties In Solibri to be fire rated or it should be imported from modeling Software?

    No, this information comes from and is edited by authoring tool and needs to be exported from it and updated in Solibri.

    Hint: there is an auto update feature:
    https://help.solibri.com/hc/en-us/articles/1500004052882-Updating-Models

    Rule #172 on help.solibri.com

  • in adequate information in escape route analysis

    Locked Solved
    7
    0 Votes
    7 Posts
    1k Views
    L

    Then you must have chosen wrong in the first step. It seems like you’ve chosen to create new classification. To add a classification you have to click the Folder icon not the Paper with a green plus icon.

  • LCA extension

    Locked Solved
    4
    0 Votes
    4 Posts
    1k Views
    EricE

    @oussama-BIM said in LCA extension:

    thank you for your reply but the problem i think that i don’t have a beta testing account for solibri
    i already sent an email to [email protected] but i did not get a reply
    is there anything else to do ?
    thank you

    You have access now.

  • This topic is deleted!

    1
    0 Votes
    1 Posts
    22 Views
    No one has replied
  • Several bugs

    10
    0 Votes
    10 Posts
    2k Views
    JSNJ

    @Arnbjerg said in Several bugs:

    This have worked fine before the update.

    I assume your classificaiton works on a best match and not on a first match and does not allow multiple matches. But still, are you sure this worked in one of the last versions? By classifying “All” including the parent components you will automatically always get the children - no matter how you classify the kids. So excluding only the childs does not really have an effect as long as you always include the parent and afaik this has been the case for a while.

    What you can do is to avoid double trouble is excluding the parents (e.g. CW) and only including the children (Panels/Members/…) you want in you classification. So then excluding those child parts in rules should work. Though it might has other side effects.

  • Ceiling Height ruleset

    Locked Solved
    5
    0 Votes
    5 Posts
    862 Views
    N

    That worked! Thank you very much!! The parameters you had above measure from floor to ceiling.

Copyright © 2025 Solibri Inc. | Powered by NodeBB